Certification Manual
- 76 -
o Default is “Normal”
Programmable Flow Control Signaling, Accommodates a variety of methods of
busy terminal signaling. Choose either:
o None
o Hardware (CTS)
o Software (XOFF/XON)
o Alt Hardware (CTS gets asserted before message response)
o Alt Software (XOFF is output before message response)
o Default is “Hardware”
Transmitter Duty Cycle
Transmitter Duty Cycle % values can range from 0 to 100. 0 and 100
values cause the duty cycle management function of the encoder to be
disabled. Any value from 1 to 99 causes duty cycle management function
to be enabled. The lower the number, the greater the delays between
transmissions caused by the encoder, to accommodate the duty cycle
requirements of specific radio models attached to the WaveWare paging
encoder. If there are concerns about the duty cycle requirements of a
particular radio, duty cycle values of 33, 50, or 66 are reasonable numbers
to consider using.
Max Messages per Batch
The Max Messages per Batch value can range from 1 to 32. The
WaveWare paging encoder supports batch paging, where multiple
messages can be included in a single key up cycle on a radio. Batch
paging allows more efficient use of the radio and delivers messages
quicker, because one preamble sequence is delivered at each “Key-up” of
the radio and multiple pager IDs and messages may be interspersed in a
single transmission cycle. Optimum message batching occurs when all
pagers operate with the same data rate, such as 512 bps (bits per second).